Table 1. Error
in total mass predicted by GreenStar® versus weigh tank scale.
|
Target
Flow |
Run
Time |
GreenStar®
Total #1 |
Scale
Total #1 |
Error
Test #1 |
GreenStar®
Total #2 |
Scale
Total #2 |
Error
Test #2 |
Actual
Flow 1 |
|
kg/s |
sec |
kg |
kg |
% |
kg |
kg |
% |
kg/s |
|
1.3 |
600 |
795 |
771 |
3.1 |
792 |
770 |
2.8 |
1.28 |
|
2.1 |
420 |
904 |
900 |
0.4 |
906 |
894 |
1.3 |
2.14 |
|
4.2 |
180 |
810 |
798 |
1.5 |
797 |
770 |
0.9 |
4.35 |
|
8.4 |
180 |
1552 |
1554 |
0.1 |
1505 |
1514 |
0.6 |
8.52 |
|
12.7 |
180 |
2322 |
2329 |
0.3 |
2261 |
2248 |
0.6 |
12.71 |
|
16.9 |
120 |
2063 |
2067 |
0.2 |
2038 |
2007 |
1.5 |
16.97 |
|
21.1 |
120 |
2502 |
2573 |
2.7 |
2581 |
2512 |
2.7 |
21.19 |
1. The
actual flow is calculated using the average total mass accumulated at the weigh
scale divided by the number of seconds that the meter was delivering grain to