Broiler Facility in Kentucky

Tunnel fans on hybrid ventilated broiler house

Cooling pads on broiler house at KY broiler farm Minimum ventilator fans on broiler house
     
Layer Facility in Pennsylvania
Tunnel-ventilated broiler house. Layer hens in high-rise house. Manure storage on lower floor of high-rise layer house.
lower&winter sampling uptairs sample ports
Producer measuring fan airflow with anemometer Aisle in lower level of belt cage layer house showing sampling port for air to ammonia PMU during cold weather conditions. PMU sampling location in belt cage layer house during tunnel ventilation mode.
ammonia box Farm W sampling ports lower cages
Portable Monitoring Unit (PMU) was located in each houses’ control room for ammonia and carbon dioxide monitoring in layer houses. Close up of belt layer house air sampling ports with two filters on lines. Cold weather exhaust fan in background behind hen cages. Each house was fully characterized in relation to dimensions, equipment and management objectives.
Inoperative fan opening and tunnel inlet curtains are well-sealed with sheet plastic covered with rigid insulation during winter in cold climate broiler houses. All the Pennsylvania broiler houses used brooders for supplemental heat. Two houses used a combination of radiant brooders and unit space heaters. Control room exterior to broiler house environment. Tunnel ventilation inlet curtains closed for winter.
Bird level temperature and humidity are recorded during each 48-hour study period. Broiler houses used box inlets placed along both sidewalls for fresh air entry. During winter conditions the ammonia Portable Monitoring Unit (PMU) sampled air from in front of the minimum ventilation exhaust fan.
Ammonia emission monitoring was done for 48-hours every three weeks in each broiler house.
Broiler houses in Pennsylvania All study broiler houses use tunnel ventilation during warm weather.
Fan Development and Calibration
FANS Unit Calibration What's wrong with this fan? Rich Gates and his instrumentation class students finalize measurements
FANS Units Moving FANS Units Univ. of Illinois at Urbana-Champaign - BESS Laboratory
Fitting FANS Unit in Flow Chamber Testing FANS 'Penalty' - Bess Labs FANS Unit Installation
Precision Anemometers FANS Unit Components FANS Unit Electronics
FANS Unit Testing
Poultry house static pressure adjusted for FANS tests at ventilation controller. Each fan’s airflow in a broiler house is tested at five static pressures representing normal operating conditions. FANS unit, laptop computer for control and data recording, and static pressure gage with datalogger are used for accurate airflow estimate.
 
 